Paulamarie Fuentes

Window Detail

  Build-able Sound Control Window   GENERAL ASSEMBLY GUIDELINES FOR SOUND CONTROL WINDOWINTERIOR USE ONLY Verify all conditions, building regulations, fire codes, before placing this window. Installers or fabricators, are responsible for the overall performance and suitability of window.• Glue 1 lb. Vinyl barrier to jamb.• Apply acoustical caulking to frame opening, then place 1/2”

Window Detail Read More »

Sound Control Wall Layering Over Existing Drywall Details Using RSIC-1 Clips

  NOTE: This is using RSIC-1 Clip This is a detail for sound resistant wall construction that we commonly use and have had great results with. It is a bit unconventional as it has never been laboratory tested and the use of resilient channel over layering is not often seen. Nonetheless, it has proven to

Sound Control Wall Layering Over Existing Drywall Details Using RSIC-1 Clips Read More »

Decoupled Floor Model

  Seismic area require attachment. Simpson A35 staggered @ 48″, 6″ from end. Confirm methods and requirements from local structural engineer.   Click here Rubber Decouplers, to purchase our effective floating floor device. As ALWAYS: Verify local building code for suitability. Click here Rubber Decouplers, to purchase our effective floating floor device. For purchase, click

Decoupled Floor Model Read More »