Door Detail
Build-able Sound Control Door Click Related Links below for product information.
This details an effective way to add isolation with a minimum amount of space and difficulty. We strongly recommend all walls and ceiling be treated equally. Even though you may think one wall is more important than another, treating just a portion of the room will not yield a significant difference. SPECIFICATIONS FOR WALL
3-Layer Drywall with Vinyl Barrier Detail, New or Existing Read More »
NOTE: This is using RSIC-1 Clip This is a detail for sound resistant wall construction that we commonly use and have had great results with. It is a bit unconventional as it has never been laboratory tested and the use of resilient channel over layering is not often seen. Nonetheless, it has proven to
Sound Control Wall Layering Over Existing Drywall Details Using RSIC-1 Clips Read More »
Seismic area require attachment. Simpson A35 staggered @ 48″, 6″ from end. Confirm methods and requirements from local structural engineer. Click here Rubber Decouplers, to purchase our effective floating floor device. As ALWAYS: Verify local building code for suitability. Click here Rubber Decouplers, to purchase our effective floating floor device. For purchase, click
Decoupled Floor Model Read More »
Questions ??? Contact Steven Klein: 818-788-1238
Adding a Partition to Existing Drywall Read More »
Provided courtesy of: www.soundcontrolroom.com Users assume responsibility when implementing any information from this site. Cavity size Material 2×42×62×82×102×122×142×16 3.5 inch5.5 inch7.5 inch9.5 inch11.5 inch13.5 inch15.5 inch 3” Therm/MWR-13 fiberglass (3.5”), 2” Therm/MWR-13 fiberglass (3.5”), 4” Therm/MWR-19 fiberglass (5.5”), 4” Therm/MWR-19 fiberglass (5.5”), 4” Therm/MWR-30 fiberglass (8.5”), 4” Therm/MWR-30 fiberglass (8.5”), 4” Therm/MW * Therm/MW =
Recommendation for Insulation Read More »
Provided free of charge as a courtesy to the community. Users assume responsibility when implementing any information from this site. Guidelines for Recording Environment Areas Served by Technical Power 1. All wire shall be minimum #12 copper stranded THHN/THWN, # 10 minimum on long runs. 2. Technical power to be on dedicated panel(s) with isolated
Guidelines for Electrical Power Read More »
Provided free of charge as a courtesy to the community. Users assume responsibility when implementing any information from this site. AIR CONDITIONING ADDS UNWANTED NOISE. IT IS CRITICAL THAT THE HVAC SYSTEMS BE QUIET.Contractors are responsible to implement as many of these guidelines where applicable and propose to the owner(s) any additional methods to achieve
Guidelines for Air Conditioning Read More »